Single Com Port Texecom Panels
Should the Texecom alarm system only have one Com Port. The Olarm MAX may not be compatible due to a hardware limitation on the alarm system.
Set the UDL passcode
The UDL password must be set to 1234 for the Olarm MAX to communicate with the panel.
Check IP and port settings
Verify that the IP address and port settings on the alarm panel match those specified in the Olarm MAX install guide.
Ensure Olarm is connected to the correct Com Port
Confirm that the Olarm MAX is plugged into the same Com Port that has been configured in the panel’s programming.
Nothing connected to Com 2? Enable IP Coms on both ports
If nothing is connected to Com 2, it must still be enabled for IP communication.
Some panels require both Com Ports to be set to IP for the Olarm to be detected correctly on Com 1.
To enable IP Coms on Com 2:
Enter Engineering Code
Press Programming Menu
Press [9] (Programming Menu)
Enter [7][6]
Press [9]
Enter [3]
Press [9] [9] to exit
Final step: Reboot the panel
After updating Com Port settings:
Recheck all programming
Reboot the alarm panel with the Olarm MAX connected
Important: Always remove the capacitor from the Olarm MAX before rebooting the panel