EVO192 panels running firmware version 7.5 or above may have their serial ports blocked for third-party devices.
If you're unsure, contact your supplier for confirmation.
To check the panel’s firmware version:
Navigate to Location 4000 on the alarm panel.
If the Olarm device displays a solid red LED:
Adapter board and credentials check:
Make sure you’re using an EVO adapter board
Ensure that the PC ID and password are set to 1234
Navigate to:
Location 3011 – PC ID
Location 3012 – PC Password
If the utility keys are enabled in the app but not functioning:
PGM assignment: Confirm that the correct utility key is assigned to the PGM in the alarm panel’s programming, and ensure it's enabled in the Olarm APP.
If arming from the app ignores your updated exit delay:
Special exit delay programming: Ensure the special arming exit delay is programmed for the relevant partitions.
Navigate to:
Location 3130 – Partition 1
Location 3230 – Partition 2
Location 3330 – Partition 3
Location 3430 – Partition 4
Location 3530 – Partition 5
Location 3630 – Partition 6
Location 3730 – Partition 7
Location 3830 – Partition 8
If a panic button wired to the panel as a keyswitch doesn't trigger a panic alarm:
Keyswitch panic programming: Ensure the keyswitch is set to the Panic input option and that panic alarms are enabled for the relevant partition in the alarm panel’s programming.
Navigate to:
Location 0501 – Keyswitch 1 input (enter the module’s serial number and the input number the panic button is wired to)
Location 0601 – Keyswitch 1 parameters
In Location 0601, enter:
5 – Panic input option
The panic type: 0 – Police, 1 – Medical, 2 – Fire
On the options screen, enable the option that matches the partition (e.g. option 1 for partition 1)
Keyswitches 2 to 32 use Locations 0502–0532 (input) and Locations 0602–0632 (parameters).
Partition panic check: The panic type selected in Location 0601 must also be enabled on the partition.
Navigate to:
Location 3123 – Partition 1
Location 3223 – Partition 2
Location 3323 – Partition 3
Location 3423 – Partition 4
Location 3523 – Partition 5
Location 3623 – Partition 6
Location 3723 – Partition 7
Location 3823 – Partition 8
Enable the option that matches the panic type:
Option 1 – Panic 1 (Police, panic type 0)
Option 2 – Panic 2 (Medical, panic type 1)
Option 3 – Panic 3 (Fire, panic type 2)
Options 4 to 6 set the alarm type for Panic 1 to 3: ON = audible (fire alarm for Panic 3), OFF = report only (silent).
Note: These options also enable the keypad panic keys ([1]+[3], [4]+[6], [7]+[9]) for that partition.
Once programmed, trigger the panic and confirm with the control room that a panic signal is received, not a zone alarm.