If you're experiencing issues during or after installing Olarm MAX on an IDS X16/X64 or X-Series Serial alarm panel, follow the steps below to identify and resolve common installation problems.
If the Olarm MAX shows a red LED after connection:
Check your adapter board: Make sure you’re using the correct adapter for your panel type.
Firmware version: The IDS alarm panel must be running firmware version 2.5 or higher.
Press and hold “*” for 3 seconds until keypad beeps
Press “*” again to display panel firmware version
Location 196 configuration: Confirm that location 196 is programmed to “123456” on the alarm panel.
If you can arm the alarm from the app but disarming fails:
Master code mismatch: Ensure that the master code set on the alarm panel matches the one entered in the Olarm APP.
If the bypass function isn't working in the app:
Code permissions: Check the code properties for User 1 (master code) and ensure it has permissions to bypass zones.