Olarm CONNECT Firmware Release Notes

Olarm CONNECT Firmware Release Notes

This article summarises the changes for each firmware release for the Olarm CONNECT.
Info
In order to update the Firmware on your Olarm CONNECT, as a Primary user, please navigate to Device page then select update firmware in the Olarm APP

V3.8.3

Release Date: 06/11/2026
New Features
  1. Same as V3.8.2
  2. Support for latet Olarm CONNECT Hardware

V3.8.2

Release Date: 29/10/2026
Changes
  1. Impact and movement
    1. Fixed the sensor sending movement events non-stop on the High sensitivity setting.
    2. The sensor now always starts after a reboot, after pairing, or after a pairing attempt times out, and retries if it fails.
    3. The Olarm CONNECT no longer wastes power while the sensor is stuck.
  2. Firmware updates
    1. The blue LED now turns off as soon as the download finishes, instead of staying on and slowly fading.
  3. Battery reporting
    1. Battery voltage now keeps updating after start-up, so low-battery alerts show the real battery level.

V3.8.0

Release Date: 07/09/2026
Changes
  1. Impact and movement
    1. Movement, free-fall and knock detection now share one 10-second cooldown, so the cooldown works as expected.
    2. Knock sensitivity now matches the Olarm ENTRY. The High setting was about 2.8 times more sensitive, so expect fewer events.
  2. Siren outputs
    1. Siren outputs now switch off automatically after a safety timeout, so a siren can no longer stay on indefinitely.

V3.7.0

Release Date: 24/08/2026
Changes
  1. Impact and movement
    1. Free-fall detection now raises both sensors, matching the Olarm ENTRY.
  2. Power and battery
    1. Brownout protection has been restored.
    2. On external power with no battery pack fitted, the battery now shows as disconnected instead of low.
  3. Radio reliability
    1. A device with a failing battery no longer disrupts radio communication for other devices.