An Olarm MAX G is required for this installation.
If the Honeywell Galaxy 2 alarm system has an existing Ethernet Module & 3 Keypads, these must be removed before installing the Olarm MAX, as it will take their place.
Before connecting the Olarm MAX, ensure that you power down your alarm system.
Cut and strip the 5-pin side of the reversible peripheral cable. Wire this end of the stripped peripheral cable into the terminals found on the back of the Olarm MAX.
Red to + (Positive)
Black to GND
Green to A
Yellow to B
Cut and strip the 4-pin side of the cable and wire this stripped end of the cable into the keypad RS485 terminals found on the Honeywell Galaxy 2 (G2) panel.
Red to +12V (Positive)
Black to GND
Green to A
Yellow to B
Before programming the Honeywell G2, ensure that you power up your alarm system.
Enabling Engineering Mode
Enter the user code and press Enter
Go to location 48 for LVL 3 ACCESS
Ensure LVL 3 ACCESS is set to 1 for Enabled and press Enter to save
Press Escape until you exit the menu
Enter the Engineer Code and press Enter
Enable signalling via Ethernet module
Go to location 56 for COMMS and press Enter
Go to sub-location 6 for HW Priority and press Enter
Enter the value 4 for Ethernet and press Enter
Ensure Ethernet is set to “1” and press Enter to save
Press Escape once to go back
Configure Alarm Reporting Formats & Triggers
Go to sub-location 4 for Ethernet and press Enter
Enter the value 2 for the Alarm Report menu and press Enter
Press Enter to adjust the Format
Set to “1” for SIA and press Enter
Enter 3 to set SIA Level (0-3) and press Enter
Press Enter to check Triggers
Ensure the following Triggers are set to ON (Press Enter to adjust)
01 - Panic ON
02 - Intruder ON
03 - 24 Hour ON
06 - Fire ON
10 - Set/unset ON
Press Escape two times
Note: Unlisted triggers can be Engineers choice
Configure Alarm Reporting IP Configuration & Account Code
Enter the value 2 for Primary IP and press Enter
Press Enter to check the IP Address
Ensure IP is set to “1.1.1.1” and press Enter
Enter the value 2 for Port No. and press Enter
Ensure Port No. is set to “10002” and press Enter
Press Escape once to go back
Enter the value 4 for Account No. and press Enter
Set to “1234” and press Enter
Press Escape once to go back
Enable Remote Access
Enter the value 3 for Remote Access and press Enter
Press Enter to adjust the Access Period
Set to “0” for Full and press Enter
Enter the value 2 for Access Mode and press Enter
Ensure Access Mode is set to “1” for Direct Access and press Enter
Press Escape twice to go back
Clear Callback No. of Telecoms (IMPORTANT)
Go to sub-location 1 for Telecoms and press Enter
Enter the value 12 for Remote Access and press Enter
Enter the value 3 for Callback No. and press Enter
Clear any value entered by pressing the “B” key
Press Enter to save
Press Escape five times to exit the menu
Perform a Module Scan
Enter the Engineers Code and press Escape
The following modules will be added:
Keypad 3
Ethernet module
Once you have programmed your Honeywell G2 alarm system, and have added it to the Olarm APP. You will be prompted to enter the Master/User Code in the app. Ensure this code has all necessary permissions.