Installation of an Olarm MAX on Paradox EVO192 Alarm Systems

Installation of an Olarm MAX on Paradox EVO192 Alarm Systems

Installation Requirements

Installing an Olarm MAX on a Paradox EVO192 Alarm System requires an Olarm Paradox EVO Adapter Board.


Step 1: Connecting the Olarm MAX

Before connecting the Olarm MAX, power down your alarm system.

Plug the 4-pin side of the reversible peripheral cable into the Olarm Paradox EVO Adapter Board and plug the adapter board into the Serial port.

Cut and strip the 5-pin side of the cable. Wire this end of the cable into the terminals found on the back of the Olarm MAX.

  • Red to + (Positive)

  • Black to GND

  • Yellow to SERIAL 1

  • Green to SERIAL 2


Step 2: Power up

Once you have powered up your Paradox EV0192 alarm system, and have added it to the Olarm APP. Check/Test the functionality of the Olarm APP.


    • Related Articles

    • Installation of an Olarm MAX on Honeywell Galaxy 2 (G2) Alarm Systems

      Installation Requirements An Olarm MAX G is required for this installation. If the Honeywell Galaxy 2 alarm system has an existing Ethernet Module & 3 Keypads, these must be removed before installing the Olarm MAX, as it will take their place. Step ...
    • Installation of an Olarm MAX on Honeywell Galaxy Dimension Alarm Systems

      Installation Requirements An Olarm MAX G is required for this installation. If the Honeywell Galaxy Dimension system has an existing Ethernet Module, this must be removed before installing the Olarm MAX, as it will take its place. Step 1: Connect the ...
    • Using the Olarm MAX and its I/O ports as a communicator-only device

      The Olarm MAX can function as a dedicated communicator for monitoring legacy alarm, fire, or panic systems that aren't directly supported. To set this up: Leave the yellow and green communication wires disconnected Power up your Olarm MAX device Add ...
    • Olarm MAX Firmware Release Notes

      This article summarises the changes for each firmware release for the Olarm MAX. In order to update the Firmware on your Olarm MAX, as a Primary user, please navigate to Device Setup then to the Firmware update tab in the Olarm APP. V1.6.5 Release ...
    • Installation of an Olarm MAX on Paradox MG/SP Alarm Systems

      Installation Requirements Ensure that locations 910 & 911 (PC ID and Password) are set to the default values of 1234 or 0000. In most cases, these settings should already be configured correctly unless they were previously modified by an installer. ...