Installing an Olarm MAX on a Paradox EVO192 Alarm System requires an Olarm Paradox EVO Adapter Board.
Before connecting the Olarm MAX, power down your alarm system.
Plug the 4-pin side of the reversible peripheral cable into the Olarm Paradox EVO Adapter Board and plug the adapter board into the Serial port.
Cut and strip the 5-pin side of the cable. Wire this end of the cable into the terminals found on the back of the Olarm MAX.
Red to + (Positive)
Black to GND
Yellow to SERIAL 1
Green to SERIAL 2
Once you have powered up your Paradox EV0192 alarm system, and have added it to the Olarm APP. Check/Test the functionality of the Olarm APP.