Installing an Olarm MAX on an Orisec Alarm System requires an Olarm Orisec Adapter Board.
Enter the Engineers code (default ‘1234’) & Press the Tick key
Press the Down Arrow key until you reach 'Com Port setup' & Press the Tick key
Press the Down Arrow key to select the 'Mode'
Press the Right Arrow key until you reach 'CID Serial'
Press and hold the Left Arrow key twice to go back to the ‘programming menu’
Press the Down Arrow key until you get to ‘ARC setup’ & Press the Tick key
Press the Down Arrow key until you get to 'Account'
Press the Right Arrow key to edit the account number
Enter the relevant ‘Account Code’ & Press the Tick key
Press and hold the Left Arrow to save and go back
Press the Down Arrow key to ‘Protocol’
Press the Right Arrow key to set it as 'Contact ID'
Press the Down Arrow key until you get to 'Dial Seq'
Press the Right Arrow key to edit the dial sequence & Enter ‘66’
Press and hold the Left Arrow three times to go back to the 'programming menu'
Press the Down Arrow key until you get to 'UDL options' & Press the Tick key
Press the Down Arrow key to 'Password’
Press the Right Arrow key to edit the UDL password & Enter your relevant UDL password
Press and hold the Left Arrow four times to go back to the 'programming menu'
Press the Tick key when asked to ‘Logoff and Exit’
Enter the Engineers code (default ‘1234’) & Press the Tick key
Press the Down Arrow key to get to 'System options' & Press the Tick key
Press the Down Arrow key until you reach 'Monitor H/W'
Press the Right Arrow key to edit it
Press the Down Arrow key until you reach 'ATS path faults'
Press the Right Arrow key to toggle the checkbox to enabled
Press and hold the Left Arrow four times to save and go back
Press the Tick key when asked to ‘Logoff and Exit’
Important: Should you not have an Olarm Orisec Adapter Board, see the alternative method below, and pay special attention to the wiring on the Olarm MAX.
Before connecting the Olarm MAX, power down your alarm system.
Plug the 4-pin side of the reversible peripheral cable into the Olarm Orisec Adapter Board, and plug the adapter board into the programmed Com Port.
Cut and strip the 5-pin side of the cable. Wire this stripped end of the cable into the terminals found on the back of the Olarm MAX.
Red to + (Positive)
Black to GND
Yellow to SERIAL 1
Green to SERIAL 2
Note: If ComPort 1 is in use, the Olarm Orisec Adapter Board will not fit onto ComPort 2. Make use of the alternative wiring method. (See here)
Once you have powered up your Orisec alarm system, and have added it to the Olarm APP. You will be prompted to enter the UDL code in the app. Ensure this is the same UDL code that was programmed.