Installation of an Olarm MAX on IDS X16/64 Alarm Systems

Installation of an Olarm MAX on IDS X16/64 Alarm Systems

Requirements

IDS X16 & X64 Panels with firmware versions below 2.5 need to be updated. To check the firmware version:

  • Press and hold [*] for 3 seconds.

  • Do not enter the master code, instead press [*] again.

The Olarm X-Series Adapter is required for this installation.


Step 1: Programme your IDS Alarm System

  • Enter the installer code followed by a [*]

    • The default installer code is [9999] or [999999

    • If these do not work, please contact the alarm installer who installed / manages the alarm system

  • From the installer menu, enter the location code [196] followed by [*]

  • Enter the Serial Security Code [123456] followed by [*]

  • Press [#] button 2 to 3 times until you hear 4 to 5 beeps from the keypad, this will take you out of the installer menu

Step 2: Connect the Olarm MAX

Before connecting the Olarm MAX, power down your alarm system.

Plug the 5-pin side of the reversible peripheral cable to the Olarm IDS X-Series Adapter Board, and plug the adapter board into the Serial Port on the IDS X-Series Alarm Panel.

Wire the adapter board’s red power wire to the panel’s AUX+ terminal.

Cut and strip the 4-pin side of the cable. Wire this end of the cable into the terminals found on the back of the Olarm MAX.

  • Red to + (Positive)

  • Black to GND

  • Yellow to SERIAL 1

  • Green to SERIAL 2


Step 3: Enter the Master/User code in the Olarm APP

Once you have powered up your IDS X-Series alarm system, and have added it to the Olarm APP. You will be prompted to enter the Master/User code in the app.