Installation of an Olarm MAX on IDS X-Series Serial Alarm Systems
Installation Requirements
The IDS Plug-on Serial Adapter For 806 and X-Series Serial is required for this installation.
Open dsbpadZ2518SmRzCLUFxKVgGpxw.png Step 1: Programme your IDS X-Series Serial Alarm System
Enter the installer code followed by a [*]
The default installer code is [9999] or [999999]
If these do not work, please contact the alarm installer who installed / manages the alarm system
From the installer menu, enter the location code [196] followed by [*]
Enter the Serial Security Code [123456] followed by [*]
Press [#] button 2 to 3 times until you hear 4 to 5 beeps from the keypad, this will take you out of the installer menu
Step 2: Connect the Olarm MAX
Before connecting the Olarm MAX, power down your alarm system.
Plug the 5-pin side of the reversible peripheral cable to the IDS Plug-on Serial Adapter For 806 and X-Series Serial, and plug the adapter board into the Serial Port on the IDS X-Series Serial Alarm Panel.
Cut and strip the 4-pin side of the cable. Wire this end of the cable into the terminals found on the back of the Olarm MAX.
Red to + (Positive)
Black to GND
Yellow to SERIAL 1
Green to SERIAL 2
Open image-20250314-151313.png Step 3: Enter the Master/User code in the Olarm APP
Once you have powered up your IDS X-Series Serial alarm system, and have added it to the Olarm APP. You will be prompted to enter the Master/User code in the app.
Open image-20250314-122425.png
Related Articles
Troubleshooting an Olarm MAX installation on IDS X-Series Alarm Systems
If you're experiencing issues during or after installing Olarm MAX on an IDS X16/X64 or X-Series Serial alarm panel, follow the steps below to identify and resolve common installation problems. Olarm MAX LED state is red after connecting to the alarm ...
Olarm MAX Firmware Release Notes
This article summarises the changes for each firmware release for the Olarm MAX. In order to update the Firmware on your Olarm MAX, as a Primary user, please navigate to Device Setup then to the Firmware update tab in the Olarm APP. V1.6.5 Release ...
IDS 806 & X-Series Serial Adapter Board
The IDS 806 & X-Series Serial Adapter Board is essential for integrating the IDS 806 and IDS X-Series Serial alarm systems with the Olarm MAX. This adapter board ensures seamless communication between the Olarm MAX and these IDS alarm systems. Key ...
Installation of an Olarm MAX on IDS 806 Alarm Systems
Installation Requirements The IDS Plug-on Serial Adapter For 806 and X-Series Serial is required for this installation. Step 1: Programme your IDS 806 Alarm System Enter the installer code followed by a [*] The default installer code is [9999] or ...
Installation of an Olarm MAX on Honeywell Galaxy 2 (G2) Alarm Systems
Installation Requirements An Olarm MAX G is required for this installation. If the Honeywell Galaxy 2 alarm system has an existing Ethernet Module & 3 Keypads, these must be removed before installing the Olarm MAX, as it will take their place. Step ...