Installation of an Olarm MAX on IDS 806 Alarm Systems

Installation of an Olarm MAX on IDS 806 Alarm Systems

Installation Requirements

The IDS Plug-on Serial Adapter For 806 and X-Series Serial is required for this installation.


Step 1: Programme your IDS 806 Alarm System

  • Enter the installer code followed by a [*]

    • The default installer code is [9999] or [999999

    • If these do not work, please contact the alarm installer who installed / manages the alarm system

  • From the installer menu, enter the location code [196] followed by [*]

  • Enter the Serial Security Code [123456] followed by [*]

  • Press [#] button 2 to 3 times until you hear 4 to 5 beeps from the keypad, this will take you out of the installer menu

Step 2: Connect the Olarm MAX

Before connecting the Olarm MAX, power down your alarm system.

Plug the 5-pin side of the reversible peripheral cable to the IDS Plug-on Serial Adapter For 806 and X-Series Serial, and plug the adapter board into the Serial Port on the IDS 806 Alarm Panel.

Cut and strip the 4-pin side of the cable. Wire this end of the cable into the terminals found on the back of the Olarm MAX.

  • Red to + (Positive)

  • Black to GND

  • Yellow to SERIAL 1

  • Green to SERIAL 2


Step 3: Enter the Master/User code in the Olarm APP

Once you have powered up your IDS 806 alarm system, and have added it to the Olarm APP. You will be prompted to enter the Master/User code in the app. 



    • Related Articles

    • Installation of an Olarm MAX on Honeywell Galaxy 2 (G2) Alarm Systems

      Installation Requirements An Olarm MAX G is required for this installation. If the Honeywell Galaxy 2 alarm system has an existing Ethernet Module & 3 Keypads, these must be removed before installing the Olarm MAX, as it will take their place. Step ...
    • Installation of an Olarm MAX on Honeywell Galaxy Dimension Alarm Systems

      Installation Requirements An Olarm MAX G is required for this installation. If the Honeywell Galaxy Dimension system has an existing Ethernet Module, this must be removed before installing the Olarm MAX, as it will take its place. Step 1: Connect the ...
    • Using the Olarm MAX and its I/O ports as a communicator-only device

      The Olarm MAX can function as a dedicated communicator for monitoring legacy alarm, fire, or panic systems that aren't directly supported. To set this up: Leave the yellow and green communication wires disconnected Power up your Olarm MAX device Add ...
    • Troubleshooting an Olarm MAX installation on IDS 805 Alarm Systems

      If you're experiencing issues during or after installing Olarm MAX on an IDS 805 alarm panel, follow the steps below to identify and resolve common installation problems. Olarm MAX LED state is red after connecting to the alarm panel If the Olarm MAX ...
    • Olarm MAX Firmware Release Notes

      This article summarises the changes for each firmware release for the Olarm MAX. In order to update the Firmware on your Olarm MAX, as a Primary user, please navigate to Device Setup then to the Firmware update tab in the Olarm APP. V1.6.5 Release ...