The Olarm MAX requires Firmware Version 1.6.0 or later
Olarm DSC PowerSeries Neo Adapter Board required
Access Installer Menu
Enter the installer menu by entering the installer code (default: *8 5555).
Set Communication Path
Enter “300” to configure the panel communication path
Set Receiver 1 to "Alt Com Auto" press * to set, then press > to Receiver 2
Set Receiver 2 to "Alt Com Rec 1" press * to set
Press # to return to the main installer menu
Set System Account Codes
Enter location “310” to access System Account Codes
Press * to edit and ensure that an account code has been set, then press # to return to the previous menu
Navigate to Partition 1's account code
Press * to edit and and ensure that a account code has been set, then press # and navigate to the previous menu
NB: An account code is required for every enabled partition
Press # to return to the main installer menu
Set Communication Format
Enter location “350” to configure the communication format
Set Receiver 1 Format to "Contact ID" press * to set, then press > to Receiver 2 format
Set Receiver 2 format to "Contact ID" press * to set
Press # to return to the main installer menu
Configure Communication Options
Enter location “380” for Com Opt 1
Ensure communications are enabled; press * to toggle (set to “Y”)
Enter location “382” for Communication Option 3
Navigate to "Alternate Comm" and ensure it is enabled; press * to toggle (set to “Y”)
Enter location “383” for Communication Option 4
Navigate to "FTC Comms" and ensure it is enabled; press * to toggle (set to “Y”)
Check relevant Zone Events have been enabled
Enter location “307” to ensure all relevant zone events have been enabled
(Note: These should be enabled by default, but please verify)
If any relevant zone event is disabled, press * to toggle and enable it (set to Y)
Press # to return to the previous menu
Check relevant Event Reporting
Enter location “308” to ensure all events in Event Reporting are enabled
If any relevant event is disabled, press * to toggle and enable it (set to Y)
Press # to return to the previous menu.
Check Alarm, Tamper & Open/Closing signals are enabled on Receiver 1 for all partitions
Enter location “311-318” to configure “Partition Call Direction“
Only configure the Partitions that are enabled on the panel
ie. Partition 1-3 enabled (configure locations 311-313)
Alarm/Restore press * and ensure Receiver 1 is enabled (set to Y)
Tamper/Restore press * and ensure Receiver 1 is enabled (set to Y)
Opening/Closing press * and ensure Receiver 1 is enabled (set to Y)
Check Communication Variables
Enter location “377” for Communication Variables
Navigate to "Comms Delay" and press * to edit and set the delay to “000”
Toggle through the menu to ensure delays are as per monitoring requirements
Press # to return to the previous menu
Before connecting the Olarm MAX, power down your alarm system.
Plug the 4-pin side of the reversible peripheral cable to the Olarm DSC PowerSeries Neo Adapter board, and plug the adapter board into PC Link 2. (Do NOT use PC Link 2)
Cut and strip the 5-pin side of the cable. Wire this end of the cable into the terminals found on the back of the Olarm MAX.
Red to + (Positive)
Black to GND
Yellow to SERIAL 1
Green to SERIAL 2
Once you have powered up your DSC PowerSeries Neo alarm system, and have added it to the Olarm APP. You will be prompted to enter the Master/User code in the app.