An Olarm MAX G is required for this installation.
If the Honeywell Galaxy Dimension system has an existing Ethernet Module, this must be removed before installing the Olarm MAX, as it will take its place.
Important: There are 2 methods to connect the Olarm MAX to the Honeywell Galaxy Dimension Alarm System.
Before connecting the Olarm MAX, ensure that you power down your alarm system.
Cut and strip the 5-pin side of the reversible peripheral cable. Wire this end of the stripped peripheral cable into the terminals found on the back of the Olarm MAX.
Red to + (Positive)
Black to GND
Green to A
Yellow to B
Cut and strip the 4-pin side of the cable and wire this stripped end of the cable into the keypad RS485 terminals found on the Honeywell Galaxy Dimension panel.
Red to +12V (Positive)
Black to GND
Green to A1
Yellow to B1
Alternatively, cut and strip the 5-pin side of the cable. Wire this end of the stripped cable into the terminals found on the back of the Olarm MAX.
Green to + (Positive)
Yellow to GND
Black to A
Red to B
And plug the 4-pin side of the peripheral cable into the RS485 port located near the keypad terminals on the Honeywell Galaxy Dimension panel.
Before programming the Honeywell Dimension, ensure that you power up your alarm system.
Enabling Engineering Mode
Enter the User Code and press Enter
Go to location 48 for Eng. Access and press Enter
Press Enter to change System Access
Press Enter to adjust Engineer
Set to 1 for Enabled and press Enter to save
Press Escape until you exit the menu
Enter the Engineer Code and press Enter
Configure Alarm Reporting Formats & Triggers
Go to location 56 for Communication and press Enter
Go to sub-location 4 for Ethernet and press Enter
Enter the value 02 and press Enter for the Alarm Report menu
Press Enter to adjust the Format
Set to “1” for SIA and press Enter
Enter 4 to set SIA Level (0-4) and press Enter
Check Triggers and set to ON as required for relevant triggers
Press Escape two times
Enable Remote Access
Enter the value 03 for Remote Access and press Enter
Press Enter to adjust the Access Period
Set to “4” for Any Time and press Enter
Enter the value 2 for Mode and press Enter
Ensure Mode is set to “1” for Direct Access and press Enter
Press Escape five times to exit the menu
Perform a Module Scan
Enter the Engineers Code and press Escape
The following module will be added:
Ethernet module
Once you have programmed your Honeywell Dimension alarm system, and have added it to the Olarm APP. Check/Test the functionality of the Olarm APP.